Blue Sea Systems Automobile Battery Charger PN 7712 User Manual

Overview of Application  
Marine Electrical Products  
The ML-Series Remote Battery Switch provides high-current carrying and switching under load.  
The Remote Battery Switch should be installed close to the battery banks to avoid voltage drop.  
ML–Series  
Remote Battery Switch (RBS)  
Install a single pole double throw (SPDT) or single pole single throw (SPST) control switch in a convenient  
location near other electrical controls or companionway to allow quick access in the event of an emergency  
(see Illustration on reverse).*  
PN 7712 / PN 7712B / PN 7714 / PN 7714B  
• Magnetic Latch (ML)—draws very low current (<13 mA in the ON state and <8 mA in the OFF state) and draws  
moderate current for very short time when changing state  
• Silver alloy contacts provide high reliability for switching live loads  
• Manual control override knob provides an added level of safety allowing control with or without power,  
and offering LOCKED OFF capability for servicing  
The Manual Control Override Knob provides:  
• an added level of safety that allows manual ON-OFF control with or without power  
• LOCK OFF for servicing the electrical system  
• LED output to remotely indicate switch state  
The remote LED embedded in PN 2155 indicates a closed connection between battery bank and load, or  
between two battery banks when used as an emergency cross-connect.  
• Tin-plated copper studs for maximum conductivity and corrosion resistance  
• Label recesses for circuit identification  
• PNs 7712 and 7714 include a Remote Control Switch PN 2155  
Remote Operation. PN 2155 (SPDT, ON-ON) Remote Control Contura Switch in the ON position can either  
connect the battery bank to the load or combine two battery banks. In the OFF position it can either  
disconnect a battery bank from a load or isolate two batteries from each other.  
RBS Specifications  
Cranking Rating  
7712, 7712B  
See Table Below  
7714, 7714B  
See Table Below  
Intermittent Rating  
Continuous Rating  
Amperage Operating Current  
See Table Below  
See Table Below  
See Table Below  
See Table Below  
When changing state <4A from Main  
contacts returns to negative (blk) wire  
To connect battery bank to load, or combine  
battery banks  
Set remote switch 2155 to position marked “ON”.  
Remote LED indicates closed connection.  
When changing state <7A from Main  
contacts returns to negative (blk) wire  
In “ON” state 13mA, In “OFF” state 8mA When “ON” 13mA, When “OFF” 8mA  
To disconnect battery bank from load, or  
isolate battery banks that are connected  
Set remote switch 2155 to position marked “OFF”.  
Voltage Maximum Operating  
Live Current Switching  
Mechanical Endurance  
Control Circuit Voltage  
Terminal Stud Size  
16.5V DC Max.  
300A @ 12V DC—10,000 Cycles  
100,000 Cycles  
916.5V DC  
3/8"-16 (M10)  
32V DC Max.  
Remote LED Indicator embedded in PN 2155 SPDT ON-ON Contura Switch  
indicates Remote Battery Switch state or condition as follows:  
150A @ 24V DC—10,000 Cycles  
100,000 Cycles  
832V DC  
3/8"-16 (M10)  
140 in-lb (15.5 N•m)  
3/8", M10  
LED INDICATION  
LED is OFF  
REMOTE BATTERY SWITCH STATE OR CONDITION  
Remote Battery Switch is OFF  
Maximum Terminal Stud Torque  
Ring Terminal Size  
140 in-lb (15.5 N•m)  
3/8", M10  
LED is ON  
Remote Battery Switch is ON  
Terminal Ring Diameter Clearance 1.18" (30.0mm)  
1.18" (30.0mm)  
Manual override--check Remote Battery Switch for switch states.  
OR Remote Battery Switch mechanical failure  
LED double blinking ON-OFF  
Regulatory Meets ISO 8846 and SAE J1171 external ignition protection requirements, Rated IP66  
Remote Control Switch 2155 Specifications  
Emergency Manual Control Override Operations  
Action  
SPDT, ON-ON  
Maximum Operating Amperage  
Seals  
Operating Temperature Range  
Mounting Hole  
20A @ 12V DC | 15A @ 24V DC  
Internal & External Gasket Panel Seal  
40°C to 85°C  
To connect battery bank to load,  
or combine battery banks  
With Override Knob in (REMOTE position),  
push button until latched (Push to Latch On).  
-
1.450"x 0.830" (36.00mm x 21.08mm)  
LED Rating  
100,000 hours 1/2 life, 20 mA @ 14V  
To disconnect battery bank from  
load, or isolate battery banks that  
are connected  
Rotate Override Knob to right to release button  
from Latch On mode (button pops up). Rotate  
Override Knob to left (REMOTE position).  
1
2
Regulatory Meets ISO 8846 and SAE J1171 external ignition protection requirements, Rated IP67  
Wire Size (AWG)  
Cranking 10 sec.  
Cranking 1 min.  
Intermittent 5 min. Continuous (UL 1107)  
2/0  
4/0  
2x (4/0)  
2,000A  
2,000A  
2,500A  
750A  
750A  
1,100A  
400A  
400A  
700A  
225A  
300A  
500A  
Rotate Override Knob to right  
(LOCK OFF position).  
To prevent remote operation  
To secure for servicing  
Manual Control  
Control Circuit  
Remote Control  
Switch Included  
PN  
Termination  
With Override Knob in (LOCK OFF position),  
pass cable tie through hole.  
7712  
7712B  
7714  
Tinned Wires  
Tinned Wires  
Tinned Wires  
Tinned Wires  
Yes  
Yes  
Yes  
Yes  
12V DC  
12V DC  
24V DC  
24V DC  
SPDT, ON-ON  
-
SPDT, ON-ON  
-
7714B  
425 Sequoia Drive  
Bellingham, WA 98226 USA  
p 360.738.8230  
Predicted performance  
p 800.222.7617 USA and Canada  
f 360.734.4195  
* Although a SPST switch may be used if desired, use of a SPDT switch improves immunity to inadvertent  
switching if the controls become damp.  
 
980010060 Rev.002  

Black Box Multi tool MPSH16 D20 120V User Manual
Black Decker Cordless Drill 5145557 04 User Manual
Blue Rhino Charcoal Grill CBT721W User Manual
Blue Sea Systems Marine GPS System PN9112 User Manual
Bostitch Impact Driver BTC440LB User Manual
Cabletron Systems Network Card 36 User Manual
Cannon Electric Pressure Cooker 10540G User Manual
CDA Range RV 1001 User Manual
Channel Vision Digital Camera 6401 User Manual
Chicago Electric Cordless Saw 93218 User Manual