Bosch Appliances Home Security System D7212GV4 User Manual

Control Panels  
D9412GV4/D7412GV4/D7212GV4  
en Owner's Manual Supplement  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
1.0  
2.0  
Introduction  
4
4
General Commands  
2.1  
2.2  
Two-Man Rule  
4
5
Early Ambush  
2.3  
2.4  
2.5  
2.6  
2.7  
2.8  
2.9  
Easy Exit Control  
5
Passcode Follows Scope  
Passcode Controlled Menu  
Walk Tests  
6
7
8
Door Activated Custom Function  
Passcode Functions  
Access Level Control  
11  
11  
13  
14  
18  
19  
2.10 Door Control  
2.11 Delete User [COMMAND 53]  
2.12 Add/Change User - [COMMAND 56]  
3.0  
SIA CP-01 Compliance Information  
27  
3.1  
3.2  
3.3  
3.4  
3.5  
3.6  
3.7  
3.8  
3.9  
System Requirements  
27  
27  
28  
29  
30  
30  
31  
31  
31  
False Alarm Reduction Features  
User-Caused False Alarms, Arming the System  
User-Caused False Alarms, Disarming the System  
Arming and Disarming with Keyswitches  
Alarm Transmission Sequence – Alarm Abort  
Cancel Report and Cancel Window  
Duress Alarm  
Swinger Shutdown  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
3
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
1.0 Introduction  
This document supplements the Security System Owner’s Manual  
(P/N: 71-06633-000) with the features for the GV4 Series. The  
instructions for the commands listed in this document replace  
those commands in the Security System Owner’s Manual. Refer to  
the Owner’s Manual for the operation of your new security system  
and its other basic features.  
Place this supplement inside the Security System  
Owner’s Manual.  
2.0 General Commands  
2.1 Two-Man Rule  
2.1.1 Description  
The Two-Man Rule adds an extra step to the disarming process by  
requiring two unique passcodes to disarm an area from the same  
keypad.  
I have this feature.  
I do not have this feature.  
2.1.2 Using the Two-Man Rule  
1. Ensure that the keypad shows idle armed text or DISARM NOW.  
2. Enter a valid passcode with the authority to Passcode Disarm  
by pressing the passcode digits followed by the [ENTER] or  
[ENT] key.  
3. The keypad shows a request for the SECOND CODE:  
4. Enter a second valid passcode with the authority to Passcode  
Disarm by pressing the passcode digits followed by the  
[ENTER] or [ENT] key. The second passcode must be different  
from the first passcode.  
The area is disarmed and ready for entry.  
4
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
2.2 Early Ambush  
2.2.1 Description  
Early Ambush adds an extra step to the disarming process by  
requiring the entry of an additional passcode to confirm that the  
area is secure. The second passcode can be same as the first or  
different, depending upon the configuration. The first entry  
disarms the area and the second entry stops an automatic timer  
from sending a duress event.  
I have this feature.  
I do not have this feature.  
2.2.2 Using Early Ambush  
1. Ensure that the keypad shows idle armed text or Disarm Now.  
2. Enter a valid passcode with the authority to Passcode Disarm  
by pressing the passcode digits followed by the [ENTER] or  
[ENT] key.  
3. Ensure that the keypad shows idle disarmed text.  
4. You can now search the area; however, you must enter the  
second passcode before the preset Early Ambush Time  
expires.  
5. Enter a second valid passcode with the authority to Passcode  
Disarm by pressing the passcode digits followed by the  
[ENTER] or [ENT] key.  
6. The keypad shows CODE 2 VALIDATEDto confirm that the  
second passcode is accepted and the Early Ambush Window is  
canceled. The area is disarmed and ready for entry.  
2.3 Easy Exit Control  
2.3.1 Description  
The GV4 Series Control Panels change from one armed state to  
another armed state without disarming. The Easy Exit Control  
feature decreases the number of keystrokes and simplifies system  
operation. This feature is available by default and is always on.  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
5
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
2.3.2 Using Easy Exit Control  
Switching armed states from Master to Perimeter:  
1. Ensure that the keypad shows idle master armed text.  
2. Press the [COMMAND] key. The keypad shows SYSTEM  
COMMAND.  
3. Press [3] to Perimeter Arm.  
4. The keypad display shows the Exit Delay countdown.  
5. Enter or exit from the premises.  
Switching armed states from Perimeter to Master:  
1. Ensure that the keypad shows idle perimeter armed text.  
2. Press the [COMMAND] key. The keypad shows SYSTEM  
COMMAND.  
3. Press [1] to Master Arm.  
4. The keypad shows the Exit Delay countdown.  
5. Enter or exit from the premises.  
2.4 Passcode Follows Scope  
2.4.1 Description  
The Passcode Follows Scope feature is an optional arming and  
disarming restriction that can be enabled on keypads with access  
to multiple areas. When this feature is set to NO, the keypad  
restricts Passcode Arming and Passcode Disarming to the home  
area of the keypad. When set to YES, this feature allows users to  
arm or disarm all the areas to which they and the keypad have  
access. This feature causes no restrictions to the keypad scope as  
it pertains to any command or arming method other than  
Passcode Arming or Passcode Disarming.  
I have this feature.  
I do not have this feature.  
6
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
2.4.2 Using Passcode Follows Scope  
Arming from a keypad with Panel Wide scope and Passcode  
Follows Scope enabled:  
1. Ensure that the keypad shows idle disarmed text.  
2. Ensure that you have a valid passcode with the authority to  
Passcode Arm in all areas.  
3. Enter your passcode by pressing the passcode digits followed  
by the [ENTER] or [ENT] key.  
4. The keypad shows ARMING: 12345678to indicate which areas  
are ready to enter, exit, delay and arm.  
5. The keypad shows the exit delay countdown.  
6. Exit from the premises.  
Arming from a keypad with Panel Wide scope and Passcode  
Follows Scope disabled (default):  
1. Ensure that the keypad shows idle disarmed text.  
2. Ensure that you have a valid passcode with the authority to  
Passcode Arm in all areas.  
3. Enter your passcode by pressing the passcode digits followed  
by the [ENTER] or [ENT] key.  
4. The keypad shows the exit delay countdown.  
5. Exit from the premises.  
2.5 Passcode Controlled Menu  
2.5.1 Description  
When enabled, the system prompts users to enter a passcode  
before viewing the keypad menu. The system shows the user the  
menu options allowed according to their authority level, thereby  
providing users only pertinent commands and functions.  
I have this feature.  
I do not have this feature.  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
7
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
2.5.2 Using Passcode Controlled Menus  
On a D1255 Keypad  
1. Press the [ESC] key. The keypad shows ENTER PASSCODE.  
2. Enter your passcode by pressing the passcode digits followed  
by the [ENT] key. The first menu item for which you have  
authority appears.  
On a D1260 Keypad:  
1. Press the Menu softkey in the lower right corner. The keypad  
shows ENTER PASSCODE then press [ENTER].  
2. Enter your passcode by pressing the passcode digits followed  
by the [ENTER] key.  
The first and second menu items for which you have authority  
appear.  
2.6 Walk Tests  
2.6.1 Description  
The D9412GV4, D7412GV4, and D7212GV4 have three Walk Test  
menus that allow the user to test various points that are within  
the scope of the keypad without sending a report to the central  
station.  
When performing a Walk Test, the Walk Test menu indicates that  
the menu is ready to time out, and clearly indicates on all keypads  
in the area of operation that a test is in progress. Additionally, the  
Walk Test procedure issues point trouble conditions for any 24-hr  
or fire points that remain off-normal when the Walk Test menu  
exits. After the system annunciates the trouble condition, faulted  
points are automatically swinger shunt bypassed regardless of the  
point index settings. These features are always enabled and have  
no configuration parameters. The warning tones commence 5 min  
prior to timeout.  
Test each smoke detector according to the manufacturer’s  
instructions.  
8
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
Table 1: Walk Test Menu Access  
Test Type  
Command  
Sequence  
Menu Function Name  
Point Types  
Tested  
WALK TEST ?  
Walk  
[COMMAND][4][4]  
Visible  
Perimeter and  
Interior  
FIRE TEST ?  
Fire  
[COMMAND][5][8]  
Not applicable  
Fire and 24-  
hour  
INVISIBLE TEST ?  
Invisible  
Invisible  
Perimeter and  
Interior  
I have this feature.  
I do not have this feature.  
2.6.2 Using Walk Test  
On a D1255 Keypad  
1. If you use the command sequence, press the keys shown in  
the Command Sequence column of Table 1 for the necessary  
test. The keypad shows the number of testable points within  
the scope of the keypad: ### PTS TO TEST. Proceed to Step  
5.  
2. If you use menu function list, press the [ESC] key.  
3. Press the [NEXT] key until the Menu Function Name (refer to  
Table 1) appears.  
4. Press the [ENT] key to activate the selected walk test function.  
The keypad shows the number of testable points within the  
scope of the keypad: ### PTS TO TEST  
5. Press the [NEXT] key to see VIEW UNTESTED?  
6. Press the [ENT] key to view the untested points. The keypad  
shows the total number of untested points within the keypad  
scope: ### PTS UNTESTED.  
7. Press the [NEXT] key to view the first point’s name.  
8. Press the [ENT] key to view the point’s hardware state. Refer  
to Table 2.  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
9
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
Table 2: Hardware States of Points  
Display Text  
Hardware State  
Normal  
Opened  
Shorted  
Missing  
1PT### NORMAL HW  
1PT### OPEN HW  
1PT### SHORT HW  
1PT### MISSNG HW  
9. Activate the point’s sensor and observe the appropriate state  
change.  
10. Press the [NEXT] key to advance to the next untested point  
within the scope of the keypad.  
11. Repeat Steps 8 through 10 until all points are tested.  
On a D1260 Keypad  
1. If you use the command sequence, press the keys indicated in  
the Command Sequence column of Table 1 on page 9 for the  
necessary walk test. The keypad shows the number of testable  
points within the scope of the keypad: ### pointsremain to  
be tested. Proceed to Step 5.  
2. If you use the menu function list, press the Menu softkey in the  
lower right corner.  
3. Press the Next softkey until the Menu Function Name (refer to  
Table 1 on page 9) appears.  
4. Press the corresponding softkey to activate the necessary  
Walk Test functions.  
The keypad shows the number of testable points within the  
scope of the keypad: ### pointsremain to be tested.  
5. Press the View untested Pts softkey to see ### PTS  
UNTESTED.  
6. Press the Next Pt softkey to view the first or next untested  
point:  
[Point Text]  
Area #, Pt #  
[Point State] HW  
<Exit  
Next PT>  
Prev PT>  
10  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
The point state can be NORMAL, OPEN, SHORT, or  
MISSING.  
7. Activate the point’s sensor and observe the state change.  
8. Repeat Steps 5 through 7 until all points are tested.  
2.7 Door Activated Custom Function  
2.7.1 Description  
The D9412GV4 and D7412GV4 allow a custom function to be  
activated when user credentials are presented to a D9210C Door  
Controller Reader. The custom function executes as if the user  
performed a function at the keypad that is associated with the  
door controller.  
I have this feature.  
I do not have this feature.  
2.7.2 Using Door Activated Custom Functions:  
Executing the door’s custom function by a user that has authority  
to do so when disarming the area:  
1. Ensure that the area you are about to enter is armed.  
2. Present your user credentials to the D9210C Door Controller  
Reader. The area disarms and the custom function executes.  
The area is now safe to enter.  
2.8 Passcode Functions  
The GV4 series control panels have several programmable function  
options that can be associated with a passcode entry at a  
specified keypad. Primary authentication requires a passcode  
only. Optionally, a keypad can be programmed for Dual  
Authentication where two forms of credentials are required. When  
enabled, the secondary authentication is performed with a Door  
Controller Reader using a token or a card provided by your dealer.  
Once a user’s credentials are authenticated, the configured  
function will be performed. Even though an access control device  
is used for authentication, the configured Passcode Function may  
not be an access operation.  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
11  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
I have One of the following Passcode Functions configured:  
Arm / Disarm (default) - All areas within the scope of the  
user and keypad have their arm state changed. If the  
current area is armed, it will disarm. If the current area is  
disarmed, it will arm.  
Cycle Door / Grant Access - The door associated with  
the keypad will momentarily unlock. If enabled, the  
current area will disarm or switch to perimeter armed,  
then (if enabled) a custom function will execute (refer to  
section 2.7 for details).  
Cycle Relay - A pre-configured function will momentarily  
activate.  
Auto Re-Arm - All armed areas within the scope of the  
user and keypad will restart their exit delay. If the current  
area is disarmed, no action is taken.  
2.8.1 Dual Authentication  
The GV4 Series control panels provide a dual authentication feature  
using a keypad and a door reader. When a keypad and door  
controller reader are paired together, they require two forms of  
identification from the same user before a pre-configured  
passcode function is performed. The authenticating user must  
have a passcode and a door credential assigned for the Dual  
Authentication process to allow the configured operation to be  
performed.  
I have this feature.  
I do not have this feature.  
The Dual Authentication feature is only available on the  
D9412GV4 and D7412GV4  
2.8.2 Dual Authentication Process  
The Dual Authentication process can be performed by entering a  
passcode followed by the [ENT] or [ENTER] key, then presenting  
valid access credentials to the associated Door Controller reader.  
12  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
The Dual Authentication process is also valid if the access  
credential is presented first. Access credentials are usually a token  
or a card and are provided by your dealer.  
The control panel requires the passcode and the credential of the  
same user to be presented within a configurable amount of time.  
The allowed duration of time can be between 10 to 45 seconds.  
Consult your dealer if the travel time between the keypad and the  
Door Controller reader is longer than the configured time. The  
default time is 10 seconds.  
2.9 Access Level Control  
2.9.1 Description  
Use this function to manually enable or disable access authority  
levels assigned to users. This function can be used to disable a  
user’s access level temporarily instead of deleting and adding the  
user.  
I have this feature.  
I do not have this feature.  
2.9.2 Using ACCESS LEVEL CTL?  
On a D1255 Keypad  
1. Activate the door’s custom functions. Refer to Section 2.7.2  
Using Door Activated Custom Functions.  
2. Ensure that the display shows idle disarmed text.  
3. Press the [MENU] key to enter the function list, then press  
[NEXT] repeatedly until you reach the CHANGE LEVEL CTL?  
prompt. Press [ENT].  
4. ACCESS LEVEL CTLappears, indicating that you are affecting  
the authority levels of cards or tokens and not passcodes.  
Press [ENT].  
5. ENTER LEVELappears. Enter the access authority level  
number and press [ENT].  
6. If the access level is currently disabled, LEVEL # ENABLE?  
appears. If the access level is currently enabled, LEVEL #  
DISABLE?appears. Press [ENT] to accept the choice.  
7. ENTER LEVELappears again. Press [ESC].  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
13  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
On a D1260 Keypad  
1. Activate the door’s custom functions. Refer to Section 2.7.2  
Using Door Activated Custom Functions.  
2. Ensure that the display shows idle disarmed text.  
3. Press the Menu softkey to enter the function list. Then press  
the Next softkey repeatedly until you reach the Change  
Level?prompt.  
4. Press the Change Level ? softkey. Access Control Level  
appears, indicating that you are affecting the authority levels  
of cards or tokens and not passcodes.  
5. Enter Level #:appears. Enter the access authority level  
number and press [ENTER].  
6. If the access level is currently disabled, Enable Level?  
appears. If the access level is currently enabled, Disable  
Level?appears. Press [ENTER] to accept the choice.  
7. Repeat Steps 5 and 6 as necessary.  
2.10 Door Control  
2.10.1 Description  
The door control function has three sub-functions:  
CYCLE DOOR?  
UNLOCK DOOR?  
SECURE DOOR?  
CYCLE DOOR?unlocks a door briefly to allow a person into an  
area.  
UNLOCK DOOR?unlocks a door to allow free access.  
SECURE DOOR?locks a door and prohibits access regardless of a  
user’s authority level.  
I have this feature.  
I do not have this feature.  
2.10.2 Using Door Control?  
On a D1255 Keypad  
1. Ensure that the display shows idle disarmed text.  
2. Press the [COMMAND] key. The display shows SYSTEM  
COMMAND.  
3. Press [4] and [6].  
14  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
You can use the function list in place of steps 2 and 3 to  
start this function.  
1. Press the [MENU] key to enter the function list.  
2. Press [NEXT] repeatedly until you reach the DOOR  
CTRL?prompt.  
3. Press [ENT].  
4. The first sub-function that appears is CYCLE DOOR?. You can  
cycle through the three sub-functions by pressing [PREV] and  
[NEXT].  
On a D1260 Keypad  
1. Ensure that the display shows idle disarmed text.  
2. Press the [COMMAND] key. The display shows *System  
Command*.  
3. Press [4] and [6].  
You can use the function list in place of steps 2 and 3 to  
start this function.  
1. Press the Menu softkey to enter the function list.  
2. Press the Next softkey repeatedly until you reach the  
Door Control?softkey.  
3. Press the Door Control ? softkey.  
4. All authorized door control function sub-functions are listed.  
Press the corresponding softkey to enter the sub-function.  
2.10.3 Cycle Door?  
1. To unlock an access door briefly and allow a person into an  
area, press [ENT] at the Cycle Door?prompt.  
The display shows CYCLE 1 2 3 4 5 6 7 8if all doors are in  
a normal state and available. If a door is not in a normal state,  
the number of the door is replaced with one of the symbols  
indicated in Table 3.  
Depending on your keypad, the operations in this  
section are the same, but the keypad display and keys  
are slightly different.  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
15  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
Table 3: Key to Symbols  
Symbol  
---  
Description  
Door is not active, not in scope, or user does not  
have access level authority  
C
U
X
P
Door is timed door sequence  
Strike and shunt are latched active (held open)  
Strike and shunt are deactivated (secured)  
There is a problem with the door; call your security  
company  
2. Enter the number of the door to cycle then press [ENT]. This  
door cycles and the display changes to reflect the new status  
of the doors. For example, to cycle Door 3, at the  
CYCLE DOOR 1 2 3 4 5 6 7 8prompt, press [3], then press  
[ENT]. The display shows CYCLE DOOR 1 2 C 4 5 6 7 8.  
This indicates that all doors are in a normal state, except for  
Door 3, which is cycled.  
3. Press [ESC] to leave this sub-function, or enter another door  
number to cycle.  
2.10.4 Unlock Door?  
Depending on your keypad, the operations in this  
section are the same, but the keypad display and keys  
are slightly different.  
1. To unlock a door to allow free access, at the CYCLE DOOR?  
prompt, press [NEXT] to enter the UNLOCK DOOR?  
sub-function.  
2. The display shows UNLOCK 1 2 3 4 5 6 7 8if all doors are  
in a normal state and available. If a door is not in a normal  
state, the number of the door is replaced with a symbol  
indicated in Table 3 on page 16.  
3. Enter the number of the door to unlock then press [ENT]. This  
door unlocks and the display changes to reflect the new status  
of the doors.  
For example, to unlock Door 4, at the following prompt,  
press [4], then press [ENT].  
UNLOCK DOOR 1 2 3 4 5 6 7 8  
16  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
The display shows UNLOCK DOOR 1 2 3 U 5 6 7 8  
This indicates that all doors are in a normal state, except for  
Door 4, which is unlocked.  
4. Press [ESC] to leave this sub-function, or enter another door  
number to unlock.  
2.10.5 Secure Door?  
Depending on your keypad, the operations in this  
section are the same, but the keypad display and keys  
are slightly different.  
1. To secure a door to prohibit access to users regardless of their  
access authority level, at the CYCLE DOOR?prompt, press  
[PREV] to enter the SECURE DOOR?sub-function.  
2. The display shows SECURE 1 2 3 4 5 6 7 8if all doors are  
in a normal state and available. If a door is not in a normal  
state, the number of the door is replaced with a symbol  
indicated in Table 3 on page 16.  
3. Enter the number of the door to secure then press [ENT]. This  
door secures, and the display changes to reflect the new  
status of the doors.  
For example, to secure Door 5, press [5], then press [ENT] at  
the following prompt: SECURE DOOR 1 2 3 4 5 6 7 8  
The display shows SECURE DOOR 1 2 3 4 X 6 7 8. This  
indicates that all doors are in a normal state, except for  
Door 5, which is secured.  
4. Press [ESC] to leave this sub-function, or enter another door  
number to unlock.  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
17  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
Each of these sub-functions acts as a toggle switch. To  
return a door to its normal state, follow the same  
procedure used to change its state. For example, if  
Door 3 is secured, to return it to its normal state, at  
the SECURE DOOR?prompt, enter [3] and press [ENT].  
The door is no longer secured and the X is replaced  
with the number 3.  
2.11 Delete User [COMMAND 53]  
2.11.1 Description  
Use this function to delete a personal passcode from your system  
without assistance from your security company. You must know  
the user number for the passcode you want to delete.  
I have this feature.  
I do not have this feature.  
2.11.2 Using DEL USER ?  
1. Ensure that the display shows idle disarmed text.  
2. Press the [COMMAND] key. The display shows SYSTEM  
COMMAND.  
3. Press [5] and [3].  
You can use the function list in place of steps 2 and 3  
to start this function.  
1. Press the [MENU] key to enter the function list.  
2. Press [NEXT] repeatedly until you reach the DEL  
USER? prompt.  
3. Press [ENT].  
4. The display shows DEL USER #. Enter the user number and  
press [ENT].  
5. USER ##(or user text, such as the name of the user, if this  
feature was programmed into your system by your security  
company) appears, allowing for confirmation. Press [ENT].  
If this is not the user you wish to delete, press the [NEXT] or  
[PREV] key until the correct user name appears, then press  
[ENT].  
18  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
6. The display shows DELETE USER ##?. Press [ENT] to delete  
user, and USER DELETEDappears. If the user number is not in  
the system, NOT IN USEappears. If you made an error and do  
not wish to delete this user, press [ESC].  
2.12 Add/Change User - [COMMAND 56]  
2.12.1 Description  
Use this function to add or change a passcode or card without  
assistance from your security company. Before adding or changing  
a passcode or card, you must know which user numbers are  
available, the authority level you want to assign to the new user,  
and the areas in which the passcode or card are valid.  
I have this feature.  
I do not have this feature.  
2.12.2 Using Add User ?  
On a D1255 Keypad  
1. Ensure that the display shows idle disarmed text.  
2. Press the [COMMAND] key. The display shows SYSTEM  
COMMAND.  
3. Press [5] and [6]. Enter passcode if necessary.  
You can also use the function list in place of Steps 2  
and 3 to start this function.  
1. Press the [MENU] key to enter the function list.  
2. Press [NEXT] until you reach the ADD/CHNG USER?  
prompt.  
3. Press [ENT].  
4. The display shows ENTER USER #. Enter the user number and  
press [ENT].  
5. The display shows USER # (or user text, such as the name of  
the user, if this feature was programmed into your system by  
your security company) to allow for confirmation.  
Press [ENT] if the correct user number (or user name)  
appears. Press [ESC] if not.  
6. ADD PASSCODE?appears. (If the user number already exists,  
CHANGE PASSCODE?Appears.) Press [ENT].  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
19  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
7. ENTER NEW CODEappears. Enter the new passcode followed  
by [ENT]. ENTER AGAINappears.  
8. Enter the new passcode a second time for confirmation. Press  
[ENT]. The display shows PASSCODE ADDED(or PASSCODE  
CHANGEDif the user number was already in the system).  
For systems with access control, the following  
prompts are available: ADD CARD? and CHANGE  
CARD?.Refer to Systems With Access Control on page  
22 for details.  
The system does not accept a passcode that is within  
two digits of an existing passcode. This is to avoid  
conflicts with duress passcodes. For example, if  
passcode 123 is already programmed in the system,  
the system does not accept 121, 122, 124, or 125 as  
passcodes.  
9. ADD LEVEL?appears. If the user number already exists,  
CHANGE LEVEL?appears. Press [ENT].  
10. VALID AREA 1? appears. If you wish this user number to be  
valid in Area 1, press [ENT]. If not, press [NEXT].  
11. AUTH LEVELappears. Assign the authority level you wish the  
user number to have for this area and press [ENT]. Record this  
information.  
12. VALID AREA 2?appears. Enter the information necessary for  
the areas in the scope of the keypad by following Steps 10 and  
11 for each area (up to 8 areas).  
13. LEVEL ADDEDor LEVEL CHANGEDappears when all area  
assignments are made. Press [ENT].  
At the end of each function, press [ESC] to return to  
the ENTER USER #prompt. Press [ESC] again to return  
to idle text.  
On a D1260 Keypad  
14. Ensure that the display shows idle disarmed text.  
15. Press the [COMMAND] key. The display shows *System  
Command*.  
16. Press [5] and [6]. Enter passcode if necessary.  
20  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
You can also use the function list in place of steps 2 and  
3 to start this function.  
1. Press the Menu softkey to enter the function list.  
2. Press the Next softkey until you reach the  
Add/Change User?prompt.  
3. Press the corresponding softkey. Proceed to step 4.  
17. The display shows Add / Change User Enter user #:  
Enter the user number and press [ENTER].  
18. The display shows User ###followed by the configured user  
name text. Press the Continue softkey if the correct user  
number (and user name) appears. Press the Exit softkey and  
return to step 4.  
19. The Add/Change Menuappears. Press the Passcode softkey.  
20. Add a passcode for this user?appears with the  
configured user name text at the top. Press the Yes softkey.  
21. Enter new passcodeappears. Enter the new passcode  
followed by [ENTER]. Enter new passcode again.appears.  
22. Enter the new passcode a second time for confirmation. Press  
[ENTER]. The display shows Passcode Added or Passcode  
Changed.  
23. Add Auth. Level for this User?appears. Press the Yes  
softkey.  
24. Is this user authorized in Area 1?appears. Press the  
Yes softkey if authorized, No if not.  
25. User's Current authority level: #appears. Enter the  
new level followed by [ENTER] to accept.  
26. Is this user authorized in Area 2?appears. Press the  
Yes softkey if authorized, No if not.  
27. User's Current authority level: #appears. Enter the  
new level followed by [ENTER] to accept. Repeat Steps 26 and  
27 until all authorized areas are set.  
28. Level Addedor Level Changedappears when all area  
assignments are made. Press [ENTER].  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
21  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
Systems With Access Control  
If your system includes access control features, such as card  
readers at doors, the following prompts can appear during the  
ADD USER? procedure.  
On a D1255 Keypad  
ADD CARD? (CHANGE CARD?)  
1. If the user has card or token access to the building or area,  
press [ENT] at the ADD CARD?prompt, or at the CHANGE  
CARD?prompt if the user already has a card or token.  
2. PRESENT CARDappears. Present the card at the card reader  
and wait for the tone.  
3. If the reader identifies the card or token correctly, a tone  
sounds and the keypad shows CARD ADDED, or CARD  
CHANGEDif the user already has a card or token. Press [ENT].  
On a D1260 Keypad  
1. From the Add/Change Menu,press the Card softkey.  
2. Add Access Card for this user?appears. Press the Yes  
softkey.  
3. Present card to card reader # now.appears. Present  
access credentials to the associated door reader and wait for a  
tone.  
4. If the reader identifies the credential correctly, a tone sounds  
and the keypad shows Card Added or Card Changedif the  
user already has a card or token. Press [ENTER].  
2.12.3 Systems with Wireless Keyfobs  
If your system has wireless services available, the following  
options are available to enroll, remove or replace a User Keyfob  
provided by your security company.  
I have this feature.  
I do not have this feature.  
Enrolling a User Keyfob with RFID  
On a D1255 Keypad  
1. Ensure that the display shows idle disarmed text.  
22  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
2. Press the [COMMAND] key. The display shows *System  
Command*.  
3. Press [5] and [6]. Enter passcode if necessary.  
4. At the USER KEYFOBS?prompt, press [ENT].  
5. ENTER RFIDappears. Press [ENT].  
6. USER ###: KEYFOBappears scrolling with NOT ASSIGNED.  
Press [ENT].  
7. RFID:prompt appears. Enter the RFID number provided by  
your security company. Press [ENT] when done.  
8. PARAMETER SAVEDappears, then USER ###: KEYFOBscrolling  
with the RFID number.  
On a D1260 Keypad  
1. From the Add/Change Menupress the Keyfob softkey.  
2. Configure RF Keyfob for this user?appears. Press the  
Yes softkey.  
3. Select the Enter Keyfob RFID softkey. Keyfob User (###)  
RFID: Not Assignedappears.  
4. Press the Edit softkey. The RFID:prompt appears.  
5. Enter the RFID number provided by your security company.  
Press the Save softkey when finished.  
6. PARAMETER SAVEDappears, then Keyfob User (###) RFID:  
########appears. Press the Exit softkey.  
Enrolling a User Keyfob with Auto-learn  
On a D1255 Keypad  
1. At the USER KEYFOBS?prompt, press [ENT].  
2. ENTER RFIDappears. Press [NEXT] until ADD KEYFOBappears.  
Press [ENT].  
3. KEYFOB USER: ###appears scrolling with NOT ASSIGNED.  
Press [ENT] to activate Auto-Learn mode.  
4. ADDING (###)appears scrolling with RESET XMITTER. Press  
the [RESET] button on the Keyfob.  
5. If successful, KEYFOB ADDEDappears. KEYFOB USER: ###  
appears scrolling with AUTO-LEARNED. Press [ESC] to exit.  
6. If not successful, an error message is displayed. KEYFOB USER:  
### appears scrolling with NOT ASSIGNED. Press [ESC] to exit.  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
23  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
On a D1260 Keypad  
1. From the Add/Change Menupress the Keyfob softkey.  
2. Configure RF Keyfob for this user?appears. Press the  
Yes softkey.  
3. Press the Add Keyfob softkey. Keyfob User (###) RFID:  
Not Assignedappears.  
4. Press the Add softkey. Adding Keyfob: (###) Press  
Xmitter Resetappears. Press the [RESET] button on the  
keyfob.  
5. If successful, Keyfob Addedappears followed by Keyfob  
User (###) RFID: Auto-Learned. Press the Exit softkey.  
6. If not successful, an error message is displayed followed by  
Keyfob User (###) RFID: Not Assigned. Press the Exit  
softkey.  
24  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
Replace a User Key Fob  
On a D1255 Keypad  
1. At the USER KEYFOBS?prompt, press [ENT].  
2. ENTER RFIDappears. Press [NEXT] until REPLACE KEYFOB  
appears. Press [ENT].  
3. KEYFOB USER: ###appears scrolling with AUTO-LEARNEDif the  
keyfob to be replaced was auto-learned, or KEYFOB USER (###)  
RFID: {assigned RFID #} appears. Press [ENT].  
4. REPLACING (###)appears scrolling with RESET XMITTER.  
Press the [RESET] button on the Keyfob.  
5. If successful, KEYFOB ADDEDappears. KEYFOB USER: ###  
appears scrolling with AUTO-LEARNED. Press [ESC] to exit.  
6. If not successful, an error message is displayed. KEYFOB USER:  
###appears scrolling with NOT ASSIGNED. Press [ESC] to exit.  
On a D1260 Keypad  
1. From the Add/Change Menupress the Keyfob softkey.  
2. Configure RF Keyfob for this user?appears. Press the  
Yes softkey.  
3. Press the Replace Keyfob softkey. Keyfob User: ###  
appears scrolling with Auto-Learnedif the keyfob to be  
replaced was auto-learned, or Keyfob User (###) RFID:  
{assigned RFID #} appears.  
4. Press the Replace softkey. Replacing Keyfob: (###)  
Press Xmitter Resetappears. Press the [RESET] button on  
the Keyfob.  
5. If successful, Keyfob Addedappears followed by Keyfob  
User (###) RFID: Auto-Learned. Press the Exit softkey.  
6. If not successful, an error message is displayed followed by  
Keyfob User (###) RFID: Not Assigned. Press the Exit  
softkey.  
Remove a User Keyfob  
On a D1255 Keypad  
1. At the USER KEYFOBS?prompt, press [ENT].  
2. ENTER RFIDappears. Press [NEXT] until REPLACE KEYFOB  
appears. Press [ENT].  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
25  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
3. KEYFOB USER: ###appears scrolling with AUTO-LEARNED.  
Press [ENT] to remove a keyfob.  
4. If successful, KEYFOB REMOVEDappears. KEYFOB USER: ###  
appears scrolling with NOT ASSIGNED. Press [ESC] to exit.  
5. If not successful, an error message is displayed. KEYFOB USER:  
###appears scrolling with NOT ASSIGNED. Press [ESC] to exit.  
On a D1255 Keypad  
1. From the Add/Change Menupress the Keyfob softkey.  
2. Configure RF Keyfob for this user?appears. Press the  
Yes softkey.  
3. Press the Next softkey. Press the Remove Keyfob softkey.  
4. Keyfob User (###) RFID: {assigned RFID #}appears.  
Press the Remove softkey.  
5. If successful, Keyfob Removedappears followed by Keyfob  
User (###) RFID: Not Assigned. Press the Exit softkey.  
6. If not successful, an error message is displayed followed by  
Keyfob User (###) RFID: Not Assigned. Press the Exit  
softkey.  
26  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
3.0 SIA CP-01 Compliance Information  
Warning: The default programming for the control panel  
includes a 30-second communication delay for alarms on  
non-fire zone types. It can be removed (or increased to 45  
sec) at the option of the end user in consultation with the  
installer.  
3.1 System Requirements  
The minimum system requirements for SIA CP-01 compliance are:  
Table 4: System Requirements  
Control Panel  
D9412GV4  
D7412GV4  
D7212GV4  
Firmware Version  
1.00 or later  
1.00 or later  
1.00 or later  
3.2 False Alarm Reduction Features  
False alarms are such an issue that the local authorities in some  
jurisdictions no longer respond to alarms. The Security Industry  
Association (SIA) has developed a Control Panel False Alarm  
Reduction Standard that details design features for security  
control panels and their associated arming and disarming devices  
to reduce the occurrence of false alarms.  
This section of the user’s guide supplement will help to explain  
proper operation of your SIA CP-01 compliant Bosch Security  
Systems, Inc. D9412GV4, D7412GV4, or D7212GV4 Control Panel.  
Your installation company must configure all features  
necessary to provide SIA CP-01 compliance.  
I have this feature.  
I do not have this feature.  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
27  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
3.3 User-Caused False Alarms, Arming the System  
3.3.1 Exit Time Defaults  
The SIA standard calls for Exit Time to range from 45 sec to at  
least two min (not to exceed 255 sec).  
The default is 60 sec.  
3.3.2 Exit Tone  
The SIA standard requires that the control panel provide an Exit  
Tone to alert anyone remaining in the premises that Exit Delay is  
in process. The tone pulsing rate increases during the last 10 sec  
of Exit Time.  
The Exit Tone can be disabled only for individual keypads, not for  
the entire system.  
During the last 10 sec of Exit Delay, the control panel’s Alarm Bell  
output pulses on and off for the last 10 sec of Exit Delay.  
3.3.3 Exit Time Restart  
The SIA standard requires that the control have an option that  
restarts Exit Delay if a user follows these steps:  
1. Starts Exit Delay (arms the system)  
2. Exits and closes an Exit Delay zone.  
3. Returns through an Exit Delay zone.  
4. The control panel restarts Exit Delay (one-time restart only).  
I have this feature.  
I do not have this feature.  
3.3.4 Exit Error  
When a user leaves an Exit Delay zone faulted at the end of Exit  
Time, the control panel creates an “Exit Error” event as specified  
by the SIA standard:  
1. An Exit Delay point remains faulted at the end of Exit Delay.  
2. Entry Delay starts. Keypads show DISARM NOWand the Entry  
Tone sounds.  
28  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
3. The user does not return to stop Entry Delay. The Entry Delay  
time expires.  
4. The control panel starts the alarm transmission sequence,  
accompanied by an Exit Error report.  
3.3.5 Master Arm No Exit Feature (Unvacated Premises)  
If a user Master Arms an area and does not leave the premises (no  
Entry/Exit zones are faulted during the exit time), the control  
panel’s No Exit feature automatically shifts the Area from Master  
Armed to Perimeter Armed.  
I have this feature.  
I do not have this feature.  
3.3.6 Recent Closing  
If an alarm occurs within two min of the expiration of Exit Time,  
the control panel creates an “alarm-recent closing” event. If the  
user armed with a passcode, the user number is included in the  
recent closing report.  
Recent Closing events are not created for Fire Alarm events.  
3.4 User-Caused False Alarms, Disarming the  
System  
3.4.1 Entry Time Defaults  
The SIA standard requires an Entry Time of between 30 sec and  
4 min. The required default is 30 sec. If the system is not  
disarmed within Entry Time, the control panel creates an Alarm  
Event.  
During the Entry Time, the control panel sounds an Entry Delay  
Tone (distinct from the alarm tone).  
3.4.2 Passcode Disarms System (Area)  
When the control panel is in Entry Delay, entering a valid passcode  
disarms the system as soon as the last digit of the passcode is  
entered. No other keys are required.  
When the control panel is in Exit Delay or is armed, entry of a valid  
Passcode must be followed by an [ENTER] or [ENT] key.  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
29  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
3.5 Arming and Disarming with Keyswitches  
Arming Beeps and Flashes  
The SIA standard requires that the control panel provide a means  
to annunciate a change in arming state made from a Keyswitch.  
The Alarm Bell output pulses on twice when a user disarms with a  
remote device. The Alarm Bell output pulses on once when a user  
arms with a remote device  
3.6 Alarm Transmission Sequence – Alarm Abort  
The SIA standard requires an Alarm Abort feature. The control  
panel uses this feature to give end users an opportunity to  
acknowledge an alarm event and abort the alarm transmission.  
The following sections explain how this feature works.  
3.6.1 Abort Window  
The Abort Window is the time the end user has to acknowledge an  
alarm and effectively “abort” the control panel’s alarm response.  
The Abort Window is programmable.  
The minimum duration is 15 sec.  
The maximum duration is 45 sec.  
The default is 30 sec.  
In accordance with UL standards, the SIA standard  
intends that the combined Entry Time and Abort  
Window will not be programmed to exceed one  
minute.  
3.6.2 Passcode Acknowledges Alarm  
When the control panel is sounding an alarm, enter [passcode] +  
[ESC] to silence the alarm without disarming. Entering the first  
digit of the passcode temporarily silences the alarm at the keypad.  
If a valid passcode is not entered, the alarm begins sounding again  
after a period of about 10 sec with no keypad activity.  
30  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
 
D9412GV4/D7412GV4/D7212GV4 | Owner's Manual Supplement  
3.6.3 Alarms Acknowledged within the Abort Window  
If the end user acknowledges an alarm within the Abort Window:  
The alarm output is silenced.  
No alarm, restoral, or cancel reports are sent.  
No alarm, restoral, or cancel reports are entered in the control  
panel event log.  
3.6.4 At the End of the Alarm Abort Window  
If no user acknowledges the alarm within the Alarm Abort Window,  
the control panel sends the appropriate alarm reports.  
3.7 Cancel Report and Cancel Window  
If a user acknowledges an alarm after the Abort Window expires,  
but before Bell Time expires, the control panel sends a Cancel  
Report. The Cancel Window starts when the alarm is sent and  
stops when the Alarm Bell timer expires or a user acknowledges  
an alarm.  
3.8 Duress Alarm  
This feature allows any passcode with the Send Duress permission  
enabled to always send a Duress Alarm event upon entry. The  
Duress Alarm feature allows an installation to allocate unique  
passcodes as the main duress passcodes for all users.  
Additionally, when the SIA CP-01 compliant Duress Alarm option is  
enabled, the Passcode +1 and +2 options are disabled.  
3.9 Swinger Shutdown  
This feature allows for a control panel to automatically bypass a point  
that reports two or more alarm or trouble events within the same arm  
cycle. The maximum number of faults allowed on a point is called the  
Swinger Count. This value was set by the installer.  
Bosch Security Systems, Inc. | 9/11 | F01U245224-02  
31  
 
Bosch Security Systems, Inc.  
130 Perinton Parkway  
Fairport, NY 14450  
USA  
© Bosch Security Systems, Inc., 2011  
 

Billy Goat Yard Vacuum KD512, KD512HC, KD512HCS User Manual
Bissell Vacuum Cleaner 16W5 User Manual
Black Box Network Hardware ACU1022A User Manual
Black Decker Grinder 478306 00 User Manual
Blaupunkt Car Stereo System 7 647 523 310 User Manual
Bosch Power Tools Drill ROTOZIP RZ18V User Manual
Brother Sewing Machine vx780 User Manual
Canon Camcorder 2MC User Manual
Casio Digital Camera EX N1 User Manual
Chromalox Air Conditioner CAF 6 User Manual